Discussion:
Red Led in Tezro :(((
(too old to reply)
Rav
2006-11-10 12:03:35 UTC
Permalink
Hi,

I have a serious (?!) problem with the Tezro machine

It shut down and don't wake up anymore
no errors on L1 LCD...
no red LED on the front panel
no gfx and PROM on screen
no errors in L1 logs

one green LED during switch on turns in red LED inside Tezro after power up
button pressed....

any test procedure
any low level login for maintenance

HELP

R
Gary Heston
2006-11-10 16:06:00 UTC
Permalink
Post by Rav
Hi,
I have a serious (?!) problem with the Tezro machine
It shut down and don't wake up anymore
no errors on L1 LCD...
no red LED on the front panel
no gfx and PROM on screen
no errors in L1 logs
one green LED during switch on turns in red LED inside Tezro after power up
button pressed....
any test procedure
any low level login for maintenance
HELP
Sometimes the circuit that handles starting the power supplies gets
confused and does not operate properly. Try disconnecting the power
cord (or cords) and leave them disconnected for at least 15 minutes.
This basically resets the control circuit; it should then work when
you reconnect the power cord(s) and press the button.

If this does not solve the problem, you probably have a failure in
the power supply.


Gary
--
Gary Heston ***@hiwaay.net http://www.thebreastcancersite.com/

Astronomers have developed a definition of "planet" which excludes Pluto.
I'm developing a definition of "scientist" which excludes astronomers.